The Comparative Study of Optimal Fresh Gas Flow Used in Lack-Plus and Lack’s Circuit on Spontaneously Breathing Anaesthetized Adults

Authors

  • Theerapongpakdee S
  • Sathitkarnmanee T
  • Sucher S
  • Thananun M
  • Nonlhaopol DThe Comparative Study of Optimal Fresh Gas Flow Used in Lack-Plus and Lack’s Circuit on S

Keywords:

Lack-Plus circuit, Lack circuit, Fresh gas flow, Spontaneous breathing, Anaesthesia

Abstract

Background and objective: Lack’s circuit is a modified co-axial Mapleson A breathing system that is commonly used in spontaneously breathing anaesthetized adults. Lack-Plus circuit is a modified Lack circuit with additional intraluminal one-way valve and active gas scavenging system which can minimize fresh gas flow (FGF), save anaesthetic gas and decrease operating room environment pollution. Thus, the objective of this study was to compare the Lack-Plus and Lack’s circuit on the minimal FGF requirement with no and clinically acceptable rebreathing in spontaneously breathing anesthetized adults, and to invent the Lack-Plus circuit.

Material and Method: Our study was a randomized cross-over study. Twenty-four adult patients with BMI ≤ 30  kg/m2, under elective peripheral surgery in supine position with ASA physical status I-II were enrolled. They were allocated into group 1 (LP-L) starting with Lack-Plus then switching to Lack’s circuit or group 2 (L-LP) in reversed pattern.  After induction and intubation, anesthesia was maintained with 50% N2O/O2 and Desflurane 4 to 6% and fentanyl titration to control optimal respiratory rate in the range of 10 to 16/min. Starting with the first circuit, all patients were spontaneously breathing with FGF 4 L/min for 10 minutes, and then gradually decreased by 0.5 L/min every five minutes. End-tidal CO2 (ETCO2), inspired minimum CO2 (ImCO2), mean arterial pressure (MAP) and oxygen saturation (SpO2) were recorded until rebreathing (ImCO2 > 0 mmHg) occurred and continued until the FGF was 2.5 L/min. The anesthesia breathing circuit was then switched to the other and the procedure repeated.

Results: The minimal FGF at the point of rebreathing of Lack-Plus and Lack’s circuit were 2.7 ± 0.8 and 3.3 ± 0.5 L/min respectively; p<0.001.  At the FGF 2.5 L/min, ImCO2 were 1.5 ± 2.0 and 4.2 ± 2.6 mmHg respectively; p<0.001.

Conclusion: Lack-Plus circuit can be used safely, effectively, and requires less FGF than Lack’s circuit in spontaneously breathing anaesthetized adults.

Downloads

How to Cite

1.
S T, T S, S S, M T, DThe Comparative Study of Optimal Fresh Gas Flow Used in Lack-Plus and Lack’s Circuit on S N. The Comparative Study of Optimal Fresh Gas Flow Used in Lack-Plus and Lack’s Circuit on Spontaneously Breathing Anaesthetized Adults. SRIMEDJ [Internet]. 2015 Oct. 5 [cited 2024 Dec. 27];30(5):66. Available from: https://li01.tci-thaijo.org/index.php/SRIMEDJ/article/view/40015