Study survey of Dose-Length Product from Computed Tomography Examination in Srinagarind Hospital, Khon Kaen University

Authors

  • Wattana Wongsanon Department of Radiology, Faculty of Medicine, Khon Kaen University
  • Jiranthanln Phaorod Department of Radiology, Faculty of Medicine, Khon Kaen University
  • Petcharakorn Hanpanich Department of Radiology, Faculty of Medicine, Khon Kaen University
  • Panatsada Awikunprasert Department of Radiology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University

Keywords:

effective radiation; CTDIvol; DLP

Abstract

Background and objective: A computed tomography (CT) scanner emits radiation dose higher than other types of X-ray machines. This study aimed to compare the amount of radiation from CT examinations compared with the radiation dose reference level.

Method: Data were retrospectively collected from 1 February to 30 April 2014 on 1,200 patients underwent CT head, chest and abdominal examinations. The record of CT radiation dose index volume (CTDIvol), radiation dose length product (DLP) and the effective dose (ED) were compared with the reference dose levels.

Results: The study  found that the mean CTDIvol, DLP and ED from CT brain scan were 39.9 mGy, 689.86 mGy.cm, 1.8 ±0.8 mSv, the doses from CT chest were 25.9 mGy, 440.97 mGy.cm, 10.8±6.6 mSv and the doses from CT abdomen were 46.1 mGy, 767.83 mGy.cm, 15.5±7.3  mSv. The result also showed that the effective dose from CT abdomen was higher than the dose reference levels.

Conclusion: These routine works to the survey research of radiation dose from diagnostic prove to be necessary. The useful information can help to reduce radiation risk form different CT examinations.  Additional survey of radiation dose from other CT examinations might be required. The CT abdomen protocol should be revised in order to decrease the radiation dose.

References

1. The American Association of Physicists in Medicine Response in Regards to CT Radiation Dose and its Effects. December 17, 2009.
2. European Commission’s Radiation Protection Actions. European guidelines on quality criteria for computed tomography [Internet]. [cited Jul 12,2012]. Available from: http://www.drs.dk/guidelines/ ct/quality/htmlindex.htm.
3. Public health England. Dose from Computed tomography (CT) Examinations in the UK-2011 Review (internet). Published Sep, 2014.
4. วันนพ สุนันท์รุ่งอังคณา,สุชาวดี เชื้อมหาวัน.ปริมาณรังสีที่ผิวผู้ป่วยที่ได้รับจากการถ่ายภาพรังสีเอกซเรย์คอมพิวเตอร์ในโรงพยาบาล ในเขตภาคตะวันออก. กรมวิทยาศาสตร์การแพทย์ กระทรวงสาธารณสุข, 2556.
5. Virginia TS, John EA, Raju s, Maria AS, Anchali K, Madan R, et al. Dose reduction in CT while maintaining diagnostic confidence: diagnostic reference levels at routine head, chest and abdominal CT-IAEA-coordinated research project. Radiology 2006; 240: 828-34.
6. Committee 3 of the international Commission on Radiological protection (ICRP). Diagnostic reference levels in medical imaging: review and additional advice. A web Module by the ICRP committee. 1999 [cited Aug 2, 2010]. Available from: URL: http/www. icrp.org/docs/drl_for_web. pdf
7. Balter S, Hopewell JW, Miller DL, Wagner LK, Zelefsky MJ. Fluoroscopically guided interventional procedures: A review of radiation effects on patients’ skin and hair. Radiology 2010; 254:26–41.
8. Kalender WA, Wolf H, Sueess C. Dose reduction in CT by anatomically adapted tube current modulation: II. Phantom measurements. Med Phys 1999c; 26(11): 2248-53.
9. ศริวรรณ จูเลียง, สายัณห์ เมืองสว่าง. ปริมาณรังสีที่ใช้ในการตรวจสมองและช่องท้องด้วยเครื่องเอกซเรย์คอมพิวเตอร์. วารสารวิชาการสาธารณสุข, 2556.
10. Paul C Shrimpton, Jan T M Jansen, John D Harrison. Updated estimates of typical effective doses for common CT examinations in the UK . Br J Radiol 2016; 89(1057): 20150346. doi: 10.1259/bjr.20150346.
11. หน่วยรังสีวินิจฉัย. สถิติผู้มารับบริการตรวจด้วยเครื่อง CT.โรงพยาบาลศรีนครินทร์ มหาวิทยาลัยขอนแก่น, 2557.
12. หน่วยรังสีวินิจฉัย. ค่าเฉลี่ย CTDIvol / DLP ,ปริมาณรังสียังผลของการตรวจศีรษะ ทรวงอก และช่องท้องด้วย CT โรงพยาบาลศรีนครินทร์ มหาวิทยาลัยขอนแก่น, 2558.

Published

2020-07-21

How to Cite

1.
Wongsanon W, Phaorod J, Hanpanich P, Awikunprasert P. Study survey of Dose-Length Product from Computed Tomography Examination in Srinagarind Hospital, Khon Kaen University. SRIMEDJ [Internet]. 2020 Jul. 21 [cited 2024 Nov. 22];35(4):433-7. Available from: https://li01.tci-thaijo.org/index.php/SRIMEDJ/article/view/245517

Issue

Section

Original Articles