Cyclic Voltammetric Determination of Acetaminophen in Paracetamol Tablets

Main Article Content

Kanita Tungkananuruk*
Nipon Tungkananuruk
Duncan Thorburn Burns

Abstract

A method using cyclic voltammetry has been developed for the determination of acetaminophen in paracetamol tablets. The peak current from acetaminophen in 0.10 mol L-1 phosphate buffer pH 7.0 was measured with a glassy carbon electrode versus Ag/AgCl. The optimum step potential and scan rate were found to be 0.0005 V and 0.1000 V/s, respectively. The linear calibration range was 3-240 μg ml-1, and the detection limit and recovery were 3.0 μg ml-1 and 99.1% respectively. The results have been compared with those obtained by the USP XXII official method.


Keywords: Acetaminophen, paracetamol, cyclic voltammetry, glassy carbon electrode


Corresponding author: E-mail: Niponniyuta@yahoo.com

Article Details

Section
Original Research Articles

References

[1] Blake, M.I. and Shumaker, L.B. 1973 Differentiating Non-aqueous Tiration of Mixtures Containing Acetaminophen and Salicylamide, J. Ass. Off. Analyt. Chem., 56, 653-655.
[2] Carroll, M.A., White, E.F. and Zarembo, J.E. 1981 Over-the-counter Drug Analyses with HPLC, Analyt. Chem., 53, 1111A-1114A.
[3] McSharry, W.O. and Savage, I.V.E. 1980 Simultaneous High-Pressure Liquid-Chromatogeraphic Determination of Acetaminophen, Guaiphenesin and Dextromethorphan Hydrobromide in Cough Syrup, J. Pharm. Sci., 69, 212-214.
[4] Wang, J. and Dewald, H.D. 1984 Electrochemical Detector for Liquid Chromatography Based on a Reticulated Vitreous Carbon Electrode in a Thin-layer Cell, J. Chromat., 285, 281-287.
[5] Oztunc, A. 1982 Fluorimetric Determination of Acetamoniphen as Its Dansyl Derivative, Analyst, 107, 585-587.
[6] Afshari, J.T. and Liu, T.-Z. 2001 Rapid Spectrophotometric Method for the Quantitation of Acetamonophen in Serum, Analyt. Chim. Acta, 43, 165-169.
[7] Belal, S.F., Elsayed, M.A.H., Elwalily, A. and Abdine, H. 1979 Spectrophotometric Determination of Aceteminophen and Salicylamide through Nitrosation and Subsequent Chelation, Analyst, 104, 919-927.
[8] Elsayed, M.A-H., Belal, S.F.,Elwalily, A-f.M. and Abdine, H. 1979 Spectropgotometric Determination of Acetaminophen, Salicylamide and Codeine Phosphate in Tablets, Analyst,104, 620-625.
[9] Murfin, J.W. and Wragg, J.S. 1972 A Colorimetric Method for the Determination of Phenacetin and Paracetamol, Analyst, 97, 670-675.
[10] Das, S., Sharma, S.C., Talwar, S.K. and Sethi, P.D. 1989 Simultaneous Spectrophotometric Determination of Mefenamic Acid and Paracetamol in Pharmaceutical Preparations, Analyst, 114, 101-103.
[11] Bramwell, H., Cass, A.E.G., Gibbsm, P.N.B. and Green, M.J. 1990 Method for Determining Paracetamol in Whole Blood by Chronoamperometry following Enzymatis Hydrolysis, Analyst, 115, 185-188.
[12] Erdogdu, G. and Karagozler, A.E. 1997 Investigation and Comparison of the Electrochemical Behavior of Some Organic and Biological Molecules at Various Conducting Polymer Electrodes, Talanta, 44, 2011-2018.
[13] Gilmartin, M.A.T. and Hart, J.P. 1994 Rapid Detection of Paracetamol Using a Disposable, Surface-Modified Screen-Printed Carbon Electrode, Analyst, 119, 2431-2437.
[14] Lau, O.-W., Luk, S.-F. and Cheung, Y.P.M. 1989 Simultaneous Determination of Ascorbic Acid, Affeine and Paracetamol in Drug Formulations by Differential-Pulse Voltammetry Using a Glassy Carbon Electrode, Analyst, 114, 1047-1051.
[15] Miner, D.J., Rice, J.R., Riggin, R.M. and Kissinger, P.T. 1981 Voltammetry of Acetaminophen and Its Metabolites, Analyt. Chem., 53, 2258-2263.
[16] Navarro, I., Gonzalez-Arjona, D., Roldan, E. and Rueda, M. 1988 Determination of Paracetamol in Tablets and Blood Plasma by Differential Pulse Voltammetry, J. Pharm. Biomed. Anal., 6, 969-976.
[17] Ozkan, S.A., Uslu, B. and Aboul-Enein, H.Y. 2003 Analysis of Pharmaceuticals and Biological Fluids Using Modern Electroanalytical Techniques, Crit. Rev. Analyt. Chem., 33, 155-181.
[18] Wang, C., Hu, C.X., Leng, Z., Yang, G. and Jin, G. 2001 Differential Pulse Voltammetry for Determination of Paracetamol at a Pumice Mixed Carbon Electrode, Analyt. Lett., 34, 2747-2759.
[19] Zen, J.-M. and Ting , Y-S. 1997 Simultaneous Determination of Caffeine and Acetaminophen in Drug Formulations by Square-Wave Voltammetry Using a Chemically Modified Electrode, Analyt. Chim. Acta, 342, 175-180.