A Microfluidic Paper-based Analytical Device for Simultaneous Measurement of Albumin, Creatinine and Uric Acid in Urine based on Standard Addition Method
Main Article Content
Abstract
This work describes a simple method for the simultaneous measurement of urinary albumin, creatinine and uric acid using a standard addition approach on a microfluidic paper-based analytical device (µPAD). Hydrophobic barrier of the µPAD was created by stamping indelible ink onto a filter paper. The µPAD was designed with a flower-liked configuration. After aliquoting urine to a central sample zone, the sample flowed to ten surrounding channels, namely “the inner channels”, where the blank (water) or standard solutions had been added. The inner channels were connected to circular reagent zones where reagents had been immobilized. Tetrabromophenolphthalein ethyl ester, alkaline picrate, and a mixed solution of ferric chloride and ferric cyanide were used as the chromogenic reagents for the colorimetric detections of albumin, creatinine, and uric acid, respectively. Each reagent zone was linked with a circular detection zone through a second channel, namely “the outer channels”. The blue-, orange- and greenish-blue colored products were observed in the detection zones for the measurement of albumin, creatinine, and uric acid, correspondingly. A digital image of the µPAD was captured with a mobile phone. The color intensities were evaluated by ImageJTM and were employed for the quantitative analyses. The standard addition calibrations were found to be linear (r2 > 0.99) for the spiked analyte concentrations up to 100 mg L-1 albumin, 1000 mg L-1 creatinine, and 50 mg dL-1 uric acid. The paper platform provided high precision (RSD < 5 %) and good analytical recovery (91.8-109.7 %). Under paired t-test, the results obtained by the developed µPAD and the validating methods were not significantly different at 95 % confidence (albumin: tstat = -0.130, tcri = 3.182, creatinine: tstat = -0.133, tcri = 3.182, and uric acid: tstat = 1.119, tcri = 3.182).
Article Details
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright Transfer Statement
The copyright of this article is transferred to Current Applied Science and Technology journal with effect if and when the article is accepted for publication. The copyright transfer covers the exclusive right to reproduce and distribute the article, including reprints, translations, photographic reproductions, electronic form (offline, online) or any other reproductions of similar nature.
The author warrants that this contribution is original and that he/she has full power to make this grant. The author signs for and accepts responsibility for releasing this material on behalf of any and all co-authors.
Here is the link for download: Copyright transfer form.pdf
References
Mogensen, C.E., 1984. Microalbuminuria predicts clinical proteinuria and early mortality in maturity-onset diabetes. New England Journal of Medicine, 310, 356-360, https://doi.org/10.1056/NEJM198402093100605.
Barr, D.B., Wilder, L.C., Caudill, S.P., Gonzalez, A.J., Needham, L.L. and Pirkle, J.L., 2005. Urinary creatinine concentrations in the U.S. population: implications for urinary biologic monitoring measurements. Environmental Health Perspectives, 113(2), 192-200, https://doi.org/ 10.1289/ehp.7337.
Cook, J.D., Caplan, Y.H., LoDico, C.P. and Bush, D.M., 2000. The characterization of human urine for specimen validity determination in workplace drug testing: a review. Journal of Analytical Toxicology, 24, 579-588, https://doi.org/ 10.1093/jat/24.7.579.
Nashar, K. and Fried, L.F., 2012. Hyperuricemia and the progression of chronic kidney disease: is uric acid a marker or an independent risk factor? Advances Chronic Kidney Disease, 19(6), 386-391, https://doi.org/10.1053/j.ackd.2012.05.004.
Contois, J.H., Hartigan, C., Rao, L.V., Snyder, L.M. and Thompson, M.J., 2006. Analytical validation of an HPLC assay for urinary albumin. Clinica Chimica Acta, 367, 150-155, https://doi.org/10.1016/j.cca.2005.12.002.
Bessonova, E.A., Kartsova, L.A. and Shmukov, A.U., 2007. Electrophoretic determination of albumin in urine using on-line concentration techniques. Journal of Chromatography A, 1150(1-2), 332-338, https://doi.org/10.1016/j.chroma.2006.10.041.
Thakkar, H., Newman, D., Holownia, J.P., Davey, C.L., Wang, C.C., Lloyd, J., Craig, A.R. and Price, C.P., 1997. Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer. Clinical Chemistry, 43, 109-113, https://doi.org/10.1093/clinchem/43.1.109.
Jiang, C. and Luo, L., 2004. Spectrofluorimetric determination of human serum albumin using a doxycycline-europium probe. Analytica Chimica Acta, 506, 171-175, https://doi.org/10.1016/j.aca.2003.11.013.
Fujita, Y., Mori, I. and Toyoda, M., 1992. Determination of basic-proteins based on color reaction with the 3,4,5,6-tetrachloro-2-carboxyphenylfluorone-manganese (II) complex. Analytical Sciences, 8, 693-694, https://doi.org/10.2116/analsci.8.693.
Watla-iad, K., Sakai, T., Teshima, N., Katoh, S. and Grudpan, K., 2007. Successive determination of urinary protein and glucose using spectrophotometric sequential injection method. Analytica Chimica Acta, 604, 139-146, https://doi.org/10.1016/j.aca.2007.10.010.
Jaffé, M., 1886. Ueber den niederschlag, welchen pikrinsäure in normalem harn erzeugt und über eine neue reaction des kreatinins. Biological Chemistry, 10, 391-400, https://doi.org/10.1515/bchm1.1886.10.5.391.
Ogawa, J., Nirdnoy, W., Tabata, M., Yamada, H. and Shimizu, S., 1995. A new enzymatic method for the measurement of creatinine involving a novel ATP-dependent enzyme, N-methylhydantoin amidohydrolase. Bioscience, Biotechnology, and Biochemistry, 59(12), 2292-2294, https://doi.org/10.1271/bbb.59.2292.
Leung, E.M.K. and Chan, W., 2014. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays. Analytical and Bioanalytical Chemistry, 406, 1807-1812, https://doi.org/10.1007/s00216-013-7592-8.
Ambrose, R.T., Ketchum, D.F. and Smith, J.W., 1983. Creatinine determined by “high-performance” liquid chromatography. Clinical Chemistry, 29, 256-259.
Xiang, L.W., Li, J., Lin, J.M. and Li, H.F., 2014. Determination of gouty arthritis' biomarkers in human urine using reversed-phase high-performance liquid chromatography. Journal of Pharmaceutical Analysis, 4, 153-158, https://doi.org/10.1016/j.jpha.2013.11.003.
Remane, D., Grunwald, S., Hoeke, H., Mueller, A., Roeder, S., von Bergen, M. and Wissenbach, D.K., 2015. Validation of a multi-analyte HPLC-DAD method for determination of uric acid, creatinine, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid and 2-methylhippuric acid in human urine. Journal of Chromatography B, 998-999, 40-44, https://doi.org/10.1016/j.jchromb.2015.06.021.
Khajehsharifi, H., Pourbasheer, E., Tavallali, H., Sarvi, S. and Sadeghi, M., 2017. The comparison of partial least squares and principal component regression in simultaneous spectrophotometric determination of ascorbic acid, dopamine, and uric acid in real samples. Arabian Journal of Chemistry, 10, S3451-S3458, https://doi.org/10.1016/j.arabjc.2014.02.006.
Guo, J., 2016. Uric acid monitoring with a smartphone as the electrochemical analyzer. Analytical Chemistry, 88, 11986-11989, https://doi.org/10.1021/acs.analchem.6b04345.
Martinez, A.W., Phillips, S.T., Butte, M.J. and Whitesides, G.M., 2007. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angewandte Chemie International Edition, 46(8), 1318-1320, https://doi.org//10.1002/anie.200603817.
Yang, R.J., Tseng, C.C., Ju, W.J., Wang, H.L. and Fu, L.M., 2018. A rapid paper-based detection system for determination of human serum albumin concentration. Chemical Engineering Journal, 352, 241-246, https://doi.org/10.1016/j.cej.2018.07.022.
Yang, R.J., Tseng, C.C., Ju, W.J., Fu, L.M. and Syu, M.P., 2018. Integrated microfluidic paper-based system for determination of whole blood albumin. Sensors and Actuators B: Chemical, 273, 1091-1097, https://doi.org/10.1016/j.snb.2018.07.010.
Sittiwong, J. and Unob, F., 2016. Paper-based platform for urinary creatinine detection. Analytical Sciences. 32(6), 639-643, https://doi.org/10.2116/analsci.32.639.
Lewinska, I., Speichert, M., Granica, M. and Tymeck, L., 2021. Colorimetric point-of-care paper-based sensors for urinary creatinine with smartphone readout. Sensors and Actuators B: Chemical, 340, https://doi.org/10.1016/j.snb.2021.129915.
Kumar, A., Hens, A., Arun, R.K., Chatterjee, M., Mahato, K., Layek, K. and Chanda, N., 2015. A paper based microfluidic device for easy detection of uric acid using positively charged gold nanoparticles. Analyst, 140(6), 1817-1821, https://doi.org/10.1039/C4AN02333A.
Piermarini, S. Migliorelli, D., Volpe, G., Massoud, R., Pierantozzi, A., Cortese, C. and Palleschi, G., 2013. Uricase biosensor based on a screen-printed electrode modified with Prussian blue for detection of uric acid in human blood serum. Sensors and Actuators B: Chemical, 179, 170-174, https://doi.org/10.1016/j.snb.2012.10.090.
Chaiyo, S., Kalcher, K., Apilux, A., Chailapakula, O. and Siangproh, W., 2018. A novel paper-based colorimetry device for the determination of the albumin to creatinine ratio. Analyst, 143, 5453-5460, https://doi.org/10.1039/C8AN01122B.
Hiraoka, R., Kuwahara, K., Wen, Y., Yen, T., Hiruta, Y., Cheng, C. and Citterio, D., 2020. Paper-based device for naked eye urinary albumin/creatinine ratio evaluation. ACS Sensors, 5, 1110-1118, https://doi.org/10.1021/acssensors.0c00050.
Cincotto, F.H., Fava, E.L., Moraes, F.C., Fatibello-Filho, O. and Faria, R.C., 2019. A new disposable microfluidic electrochemical paper-based device for the simultaneous determination of clinical biomarkers. Talanta, 195, 62-68, https://doi.org/10.1016/j.talanta.2018.11.022.
Rossini, E.L., Milani, M.I., Carrilho, E., Pezza, L. and Pezza, H.R., 2018. Simultaneous determination of renal function biomarkers in urine using a validated paper-based microfluidic analytical device. Analytica Chimica Acta, 997, 16-23, https://doi.org/10.1016/j.aca.2017.10.018.
Mathaweesansurn, A., Maneerat, N. and Choengchan, N., 2017. A mobile phone-based analyzer for quantitative determination of urinary albumin using self-calibration approach. Sensors and Actuators B: Chemical, 242, 476-483, https://doi.org/10.1016/j.snb.2016.11.057.
Mathaweesansurn, A., Thongrod, S., Khongkaew, P., Phechkrajang, C.M., Wilairat, P. and Choengchan, N., 2020. Simple and fast fabrication of microfluidic paper-based analytical device by contact stamping for multiple-point standard addition assay: Application to direct analysis of urinary creatinine. Talanta, 210, https://doi.org/10.1016/j.talanta.2019.120675.
Islam, M.N., Ahmed, I., Anik, M.I., Ferdous, M.S. and Khan, M.S., 2018. Developing paper based diagnostic technique to detect uric acid in urine. Frontiers in Chemistry, 6, https://doi.org/10.3389/fchem.2018.00496.
Watla-iad, K., Sakai, T., Teshima, N., Katoh, S. and Grudpan, K., 2007. Successive determination of urinary protein and glucose using spectrophotometric sequential injection method. Analytica Chimica Acta, 604, 139-146, https://doi.org/10.1016/j.aca.2007.10.010.
Miller, J.N. and Miller, J.C., 1993. Statistics and Chemometrics for Analytical Chemistry. 4th ed. London: Pearson Education.