Deconvolution strategies for spatial localization of β-catenin protein
Main Article Content
Abstract
Wide field fluorescence microscopes (WFFM) are widely used due to their affordability and ease of use, but they suffer from a significant limitation: the images often appear blurry because light from above and below the focal plane contributes to the final image. Eliminating this out-of-focus light typically requires expensive equipment like confocal microscopes. This study aimed to address this issue by applying deconvolution algorithms to images obtained from conventional WFFM. MATLAB was used to implement adaptive histogram equalization, unsharp masking, and thresholding operations, while the Lucy Richardson algorithm was applied in Python. Both approaches successfully removed out-of-focus blur and enabled quantification of the percentage of β-catenin expression overlapping with nuclei at 0, 36, and 48 h post transfection of C33A cell lines with HPV16 & 18 E6/E7 oncogenes. Our results indicated that deconvoluted images revealed a higher percentage of β-catenin overlapping the nuclei compared to non-deconvoluted images: for example, in MATLAB, 13.63% vs. 9.23% at 0 h, 15.55% vs. 11.26% at 36 h, and 18.33% vs. 12.55% at 48 h. In Python, similar trends were observed, with the control showing 1.29% vs. 0.54%. This method is a computationally efficient and cost-effective solution for removing out-of-focus light from WFFM images, making it particularly useful for institutions with limited access to high-cost microscopy equipment.
Downloads
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
References
Al‑Taweel, R. S. H., Daway, H. G., & Kahmees, M. H. (2015). Deblurring average blur by using adaptive Lucy Richardson. Journal of College of Education, 5(2015), 75–90.
Bai, H., Che, B., Zhao, T., Zhao, W., Wang, K., Zhang, C., & Bai, J. (2022). Feature extraction of 3T3 fibroblast microtubule based on discrete wavelet transform and Lucy‑Richardson deconvolution methods. Micromachines, 13(6), Article 824. https://doi.org/10.3390/mi13060824
Bruce, M. A., & Butte, M. J. (2013). Real‐time GPU‐based 3D deconvolution. Optics Express, 21(4), 4766–4773. https://doi.org/10.1364/OE.21.004766
Chakraborti, S., Karmakar, A., Guha, R., Ngan, C., Das, R. K., & Whitaker, N. (2023). Induction of epithelial to mesenchymal transition in HPV16 E6/E7 oncogene transfected C33A cell line. Tissue and Cell, 82, Article 102041. https://doi.org/10.1016/j.tice.2023.102041
Disoma, C., Zhou, Y., Li, S., Peng, J., & Xia, Z. (2022). Wnt/β‑catenin signaling in colorectal cancer: Is therapeutic targeting even possible? Biochimie, 195, 39–53. https://doi.org/10.1016/j.biochi.2022.01.009
Grimm, J. B., & Lavis, L. D. (2022). Caveat fluorophore: An insiders’ guide to small‑molecule fluorescent labels. Nature Methods, 19, 149–158. https://doi.org/10.1038/s41592-021-01338-6
Hasan, H. K. (2016). Restoration of digital images using an iterative Tikhonov‑Miller filter [Master’s thesis, Al‑Nahrain University]. Al‑Nahrain University. https://www.nahrainuniv.edu.iq/en/node/6053
He, Z., Wang, H., Li, Y., Zhang, Z., Zhang, Y., Bi, H., & He, Y. (2021). A deconvolutional reconstruction method based on Lucy–Richardson algorithm for joint scanning laser thermography. IEEE Transactions on Instrumentation and Measurement, 70, Article 4501508. https://doi.org/10.1109/TIM.2020.3034967
Hickey, S. M., Ung, B., Bader, C., Brooks, R., Lazniewska, J., Johnson, I. R. D., Sorvina, A., Logan, J., Martini, C., Moore, C. R., Karageorgos, L., Sweetman, M. J., & Brooks, D. A. (2022). Fluorescence microscopy—An outline of hardware, biological handling, and fluorophore considerations. Cells, 11(1), Article 35. https://doi.org/10.3390/cells11010035
Hojjatoleslami, S. A., Avanaki, M. R. N., & Podoleanu, A. G. (2013). Image quality improvement in optical coherence tomography using Lucy‑Richardson deconvolution algorithm. Applied Optics, 52(23), 5663–5670. https://doi.org/10.1364/AO.52.005663
Kanthan, M. R., & Sujatha, S. N. (2016, December 15–17). Blur removal using blind deconvolution and gradient energy [Conference session]. 2016 IEEE International Conference on Computational Intelligence and Computing Research (ICCIC), Chennai, India. https://doi.org/10.1109/ICCIC.2016.7919556
Kaszak, I., Witkowska‑Piłaszewicz, O., Niewiadomska, Z., Dworecka‑Kaszak, B., Ngosa Toka, F., & Jurka, P. (2020). Role of cadherins in cancer—A review. International Journal of Molecular Sciences, 21(20), Article 7624. https://doi.org/10.3390/ijms21207624
Kaur, H., & Kaur, M. (2016). A hybrid approach for blur detection using Naïve Bayes nearest neighbor classifier. International Journal of Information Technology and Computer Science (IJITCS), 8(12), 75–82. https://doi.org/10.5815/ijitcs.2016.12.09
Khan, S. A., Hussain, S., & Yang, S. (2020). Contrast enhancement of low‑contrast medical images using modified contrast limited adaptive histogram equalization. Journal of Medical Imaging and Health Informatics, 10(8), 1795–1803. https://doi.org/10.1166/jmihi.2020.3196
Kim, B. (2021). DVDeconv: An open‑source MATLAB toolbox for depth‑variant asymmetric deconvolution of fluorescence micrographs. Cells, 10(2), Article 397. https://doi.org/10.3390/cells10020397
Kumar, A., Kumar, P., & Srivastava, S. (2022). A skewness reformed complex diffusion based unsharp masking for the restoration and enhancement of Poisson noise corrupted mammograms. Biomedical Signal Processing and Control, 73, Article 103421. https://doi.org/10.1016/j.bspc.2021.103421
Lambert, T. J., & Waters, J. C. (2017). Navigating challenges in the application of superresolution microscopy. Journal of Cell Biology, 216(1), 53–63. https://doi.org/10.1083/jcb.201610011
Lau, A., Fétick, R. J. L., Neichel, B., Beltramo‑Martin, O., & Fusco, T. (2023). Improved prior for adaptive optics point spread function estimation from science images: Application for deconvolution. Astronomy & Astrophysics, 673, Article A72. https://doi.org/10.1051/0004-6361/202245471
Liu, C., Sun, M., Wu, W., Dai, N., Guo, M., Wei, Y., Wu, X., & Fu, H. (2024). Enhancing the resolution of three‑dimensional migration images based on space‑variant point spread function deconvolution. Geophysical Prospecting, 72(5), 1672–1697. https://doi.org/10.1111/1365-2478.13477
Perrone, F., Bertolotti, A., Montemurro, G., Paolini, B., Pierotti, M. A., & Colecchia, M. (2014). Frequent mutation and nuclear localization of β‑catenin in Sertoli cell tumors of the testis. The American Journal of Surgical Pathology, 38(1), 66–71. https://doi.org/10.1097/PAS.0b013e31829cdbc6
Pietzsch, T., Preibisch, S., Tomančák, P., & Saalfeld, S. (2012). ImgLib2—generic image processing in Java. Bioinformatics, 28(22), 3009–3011. https://doi.org/10.1093/bioinformatics/bts543
Pushpa, N. B., Patra, A., & Ravi, K. S. (2023). Advances in microscopy and its applications with special reference to fluorescence microscope: An overview. In E. A. Meguid, P. L. Mishall, H. L. Nation, & P. M. Rea (Eds.), Biomedical visualisation (pp. 3–17). Springer. https://doi.org/10.1007/978-3-031-26462-7_1
Ramos‑García, P., & González‑Moles, M. Á. (2022). Prognostic and clinicopathological significance of the aberrant expression of β‑catenin in oral squamous cell carcinoma: A systematic review and meta‑analysis. Cancers, 14(3), Article 479. https://doi.org/10.3390/cancers14030479
Sage, D., Donati, L., Soulez, F., Fortun, D., Schmit, G., Seitz, A., Guiet, R., Vonesch, C., & Unser, M. (2017). DeconvolutionLab2: An open‑source software for deconvolution microscopy. Methods, 115, 28–41. https://doi.org/10.1016/j.ymeth.2016.12.015
Satish, P., Srikantaswamy, M., & Ramaswamy, N. K. (2020). A comprehensive review of blind deconvolution techniques for image deblurring. Traitement du Signal, 37(3), 527–539. https://doi.org/10.18280/ts.370321
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012). NIH Image to ImageJ: 25 years of image analysis. Nature Methods, 9(7), 671–675. https://doi.org/10.1038/nmeth.2089
Shi, R., Jin, C., Xie, H., Zhang, Y., Li, X., Dai, Q., & Kong, L. (2019). Multi-plane, wide-field fluorescent microscopy for biodynamic imaging in vivo. Biomedical Optics Express, 10(12), 6625–6635. https://doi.org/10.1364/BOE.10.006625
Sidhu, R. K., Sachdeva, J., & Katoch, D. (2023). Segmentation of retinal blood vessels by a novel hybrid technique—Principal component analysis (PCA) and contrast limited adaptive histogram equalization (CLAHE). Microvascular Research, 148, Article 104477. https://doi.org/10.1016/j.mvr.2023.104477
Somal, S. (2020). Image enhancement using local and global histogram equalization technique and their comparison. In A. K. Luhach, J. A. Kosa, R. C. Poonia, X.-Z. Gao, & D. Singh (Eds.), First International Conference on Sustainable Technologies for Computational Intelligence (ICTSCI 2019). Advances in intelligent systems and computing, Vol. 1045 (pp. 739–753). Springer. https://doi.org/10.1007/978-981-15-0029-9_58
Thakur, M., & Datar, S. (2014). Image restoration based on deconvolution by Richardson Lucy algorithm. International Journal of Engineering Trends and Technology, 14(2), 161–165. https://doi.org/10.14445/22315381/IJETT-V14P232
Valli, J., Garcia-Burgos, A., Rooney, L. M., de Melo e Oliveira, B. V., Duncan, R. R., & Rickman, C. (2021). Seeing beyond the limit: A guide to choosing the right super-resolution microscopy technique. Journal of Biological Chemistry, 297(1), Article 100791. https://doi.org/10.1016/j.jbc.2021.100791
Wu, X., & Hammer, J. A. (2021). ZEISS Airyscan: Optimizing usage for fast, gentle, super-resolution imaging. In J. Brzostowski & H. Sohn (Eds.), Confocal Microscopy: Methods and Protocols (pp. 111–130). Humana Press. https://doi.org/10.1007/978-1-0716-1402-0_5
Wu, Y., Han, X., Su, Y., Glidewell, M., Daniels, J. S., Liu, J., Sengupta, T., Rey-Suarez, I., Fischer, R., Patel, A., Combs, C., Sun, J., Wu, X., Christensen, R., Smith, C., Bao, L., Sun, Y., Duncan, L. H., Chen, J., . . . Shroff, H. (2021). Multiview confocal super-resolution microscopy. Nature, 600, 279–284. https://doi.org/10.1038/s41586-021-04110-0
Xu, C., Liu, F., Xiang, G., Cao, L., Wang, S., Liu, J., Meng, Q., Xu, D., Lv, S., Jiao, J., & Niu, Y. (2019). β-Catenin nuclear localization positively feeds back on EGF/EGFR-attenuated AJAP1 expression in breast cancer. Journal of Experimental & Clinical Cancer Research, 38(1), Article 238. https://doi.org/10.1186/s13046-019-1252-6
Yadav, S., Jain, C., & Chugh, A. (2016). Evaluation of image deblurring techniques. International Journal of Computer Applications, 139(12), 32–36. https://doi.org/10.5120/IJCA2016909492