Testing of Locally-Made Ripening Room
Keywords:
fruit ripening, ripening roomAbstract
This research is to test and evaluate performance of locally-made ripening (LMR) room. Results showed the LMR room of 240 cm. wide, 183 cm. long and 193 cm. high, was not well controllable by means of temperature and humidity. Insulation was too thin and temperature instrumentation was inefficient. Temperature variation was high as 6.6-11.8 degree C. Humidity control system could not be set to the desired level as 83% or less. Gas leakage out of the LMR room was high as 2.1 ml/min. Electrical power consumption was as 2.1-2.2 kw.
Published
How to Cite
Issue
Section
License
online 2452-316X print 2468-1458/Copyright © 2022. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/),
production and hosting by Kasetsart University of Research and Development Institute on behalf of Kasetsart University.