A comparison of the temperature distribution of the Hydroponic nutrient with different length using computational fluid dynamics
Main Article Content
Abstract
This paper aimed to compare temperature distribution of hydroponic nutrient solution of various gutter lengths using Computational Fluid Dynamic prediction. In this study, a pipe cross section and drill holes positions were consistent and flow rate of solution was 100 L/hr. The result shown that, in the depth between 5 mm to 25 mm, the temperature at the deeper solution was higher than the surface. It also shown that the different lengths of gutter in this study slightly affected the solution temperature distribution. The different lengths of gutter in this study were 6 m, 8 m, 12 m, 16 m and 20 m and the temperature increased after the length was greater than 4 m. The nutrient solution temperature was between 25.00 and 25.76 °C which was low temperature and suitable for plants.
Article Details
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของ วารสารวิทยาศาสตร์และเทคโนโลยี มหาวิทยาลัยอุบลราชธานี
ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับมหาวิทยาลัยอุบลราชธานี และคณาจารย์ท่านอื่นๆในมหาวิทยาลัยฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใดๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว