CFAE Method for Condition Assessment of Oil-Impregnated Insulating Paper of Power Transformers
Main Article Content
Abstract
Power Transformers are high-value primary equipment and important components in high voltage networks system. This makes the determination of transformer’s remaining life very important for asset management. The insulation system of most transformers is oil-paper insulation having kraft paper as solid insulation and transformer oil as liquid insulation. The insulating condition of the insulating paper is an important factor affecting the remaining life of a transformer. This is because if the transformer oil insulation deteriorates, it can be replaced throughout its service life; however, this cannot be done with the insulating paper. Therefore, checking of insulating paper’s condition is essential; but, to do it with the degree of polymerization (DP) is very difficult. This article proposed an approach to assess the transformer insulation condition by using results from the transformer oil insulator technical test consisting of oil quality testing, dissolved gas analysis, and furan compound testing in transformer oil. They were processed into the CFAE index indicating the degeneration of the insulating paper inside a transformer and used to compare with the CO2/CO ratio according to IEEE Std. C57.104 and IEC 60599 standards. If the CFAE index was between -2 and -5.3 and the CO2/CO ratio was between 3 and 10, it would ensure that the insulating paper was in usable condition and was not severely degraded inside the transformer. However, if the results conflicted, the results of the oil quality test would be used for further consideration.
Article Details
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของ วารสารวิทยาศาสตร์และเทคโนโลยี มหาวิทยาลัยอุบลราชธานี
ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับมหาวิทยาลัยอุบลราชธานี และคณาจารย์ท่านอื่นๆในมหาวิทยาลัยฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใดๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว
References
Jahromi, A. and et al. 2009. An approach to power transformer asset management using health index. IEEE Electrical Insulation Magazine. 25(2): 20-34.
Ortiz, F. and et al. 2016. Health indexes for power transformers: A case study. IEEE Electrical Insulation Magazine. 32(5): 7-17.
Islam, M.M., Lee, G. and Hettiwatte, S.N. 2017. A review of condition monitoring techniques and diagnostic tests for lifetime estimation of power transformers. Electrical Engineering. 100(2): 581-605.
Frimpong, G.K., Oommen, T.V. and Asano, R. 2011. A survey of aging characteristics of cellulose insulation in natural ester and mineral oil. IEEE Electrical Insulation Magazine. 27(5): 36-48.
Oommen, T.V. and Prevost, T.A. 2006. Cellulose insulation in oil-filled power transformers: Part II maintaining insulation integrity and life. IEEE Electrical Insulation Magazine. 22(2): 5-14.
Prevost, T.A. and Oommen, T.V. 2006. Cellulose insulation in oil-filled power transformers: Part I - history and development. IEEE Electrical Insulation Magazine. 22(1): 28-35.
Sermsukroongsakul, S. and et al. 2019. A study of remaining lifetime assessment of generator step-up transformer using degree of polymerization. In: Proceedings of the 2019 IEEE PES GTD Grand International Conference and Exposition Asia (GTD Asia), 19-23 March 2019. Bangkok, Thailand.
Singh, R.P. and et al. 2020. A review on traditional methods of condition monitoring of transformer. In: Proceedings of the 2020 International Conference on Electronics and Sustainable Communication Systems (ICESC), 2-4 July 2020. Coimbatore, India.
Lelekakis, N., Martin, D. and Wijaya, J. 2012. Ageing rate of paper insulation used in power transformers Part 2: Oil/paper system with medium and high oxygen concentration. IEEE Transactions on Dielectrics and Electrical Insulation. 19(6): 2009-2018.
Lelekakis, N., Martin, D. and Wijaya, J. 2012. Ageing rate of paper insulation used in power transformers Part 1: Oil/paper system with low oxygen concentration. IEEE Transactions on Dielectrics and Electrical Insulation. 19(6): 1999-2008.
Lelekakis, N. and et al. 2014. The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation. IEEE Electrical Insulation Magazine. 30(3): 19-26.
Kuen, C. 2010. Analysis and comparison of aging-trends of cellulose for transformers with oil-cellulose-insulation. In: Proceedings of the 2010 International Conference on High Voltage Engineering and Application, 11-14 October 2010. New Orleans, LA, USA.
Liland, K.B. and et al. 2011. Ageing of oil impregnated thermally upgraded papers. In: Proceedings of the 2011 IEEE International Conference on Dielectric Liquids, 26-30 June 2011. Trondheim, Norway.
Unsworth, J. and Mitchell, F. 1988. Degradation of electrical insulating paper monitored using high performance liquid chromatography. In: Proceedings of the 2nd International Conference on Properties and Applications of Dielectric Materials, 12-16 September 1988. Beijing, China.
Suwarno, R. and Pasaribu, R. 2017. Effects of thermal aging on paper characteristics in paper-mineral oil composite insulation. In: Proceedings of the 2017 International Symposium on Electrical Insulating Materials (ISEIM), 11-15 September 2017. Toyohashi, Japan.
Teymouri, A. and Vahidi, B. 2017. CO2/CO concentration ratio: A complementary method for determining the degree of polymerization of power transformer paper insulation. IEEE Electrical Insulation Magazine. 33(1): 24-30.
Zhang, C.H. and Macalpine, J.M.K. 2006. Furfural concentration in transformer oil as an indicator of paper ageing, part 1: A review. In: Proceedings of the 2006 IEEE PES Power Systems Conference and Exposition, 29 October-1 November 2006. Atlanta, GA, USA.
Cheim, L. and et al. 2012. FFuran analysis for liquid power transformers. IEEE Electrical Insulation Magazine. 28(2): 8-21.
Stebbins, R.D., Myers, D.S. and Shkolnik, A.B. 2003. Furanic compounds in dielectric liquid samples: Review and update of diagnostic interpretation and estimation of insulation ageing. In: Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials, 1-5 June 2003. Nagoya, Japan.
Allan, D.M. 1992. A practical life assessment technique for aged oil paper systems. In: Proceedings of the 6th International Conference on Dielectric Materials, Measurements and Applications, 7-10 September 1992. Manchester, UK.
Feng, D. and et al. 2019. Effect of oil–paper–pressboard mass ratio on furfural content in transformer oil. IEEE Transactions on Dielectrics and Electrical Insulation. 26(4): 1308-1315.
Pahlavanpour, B., Martins, M.A. and Pablo, A.D. 2002. Experimental investigation into the thermal-ageing of Kraft paper and mineral insulating oil. In: Proceedings of the Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation, 7-10 April 2002. Boston, MA, USA.
Teymouri, A. and Vahidi, B. 2021. Power transformer cellulosic insulation destruction assessment using a calculated index composed of CO, CO2, 2-furfural, and acetylene. Cellulose. 28(1): 489-502.
IEEE. 2019. IEEE Std C57.104-2019 IEEE Guide for the Interpretation of Gases Generated in Mineral Oil-Immersed Transformers. https://pdfcoffee.com/ieee-c57104-2019pdf-5-pdf-free.html. Accessed 31 January 2021.
Prasojo, R.A. and et al. 2017. Correlation of transformer paper deterioration to oil characteristics and dissolved gases. In: Proceedings of the 2017 International Conference on High Voltage Engineering and Power Systems (ICHVEPS), 2-5 October 2017. Dempasar, Indonesia.
Lee, S. and et al. 2013. New methods of DGA diagnosis using IEC TC 10 and related databases part 2: Application of relative content of fault gases. IEEE Transactions on Dielectrics and Electrical Insulation. 20(2): 691-696.