100 Seed Counter Designed for Mungbean (<I>Vigna radiata</I> (L.) Wilczek) and for Soybean (<I>Glycine max</I> (L.) Merr.)

Main Article Content

Surat Nuglor

Abstract

Seed weight was reported as the weight per 1,000 seeds of working sample. Procedure for 1,000 seed's weight determination starting from counting, eight replicates, each of 100 seeds followed by weighing and recording each replicate in grams, calculate the average weight of 1,000 seeds and multiplied by 10. Following this procedure, seed technologist should concentrate on the seed sample and counting 100 seeds by hand which take times and causing more erratum due to longer practices. By 100 seed counter designed for mungbean and for soybean make the procedure of 100 seed determination easy and saving times. Determination of 100 seed weight by this counter required an average of 10.5 and 23.4 seconds compared to 45 and 43.7 seconds by hand counting for mungbean and soybean, respectively.

Article Details

Section
Research Articles

References

ISTA, 1976. International Rules for Seed Testing. Seed Sci. and Technol. 4: 1-177.

ISTA, 1985. International Rules for Seed Testing 1985. Seed Sci. and Technol. 13(2): 342-343.

นงลักษณ์ ประกอบบุญ. 2527. บทปฏิบัติการการทดสอบเมล็ดพันธุ์. ภาควิชาพืชไร่ คณะเกษตรศาสตร์ มหาวิทยาลัยเชียงใหม่. 97 หน้า.

นงลักษณ์ ประกอบบุญ. 2528. การทดสอบคุณภาพเมล็ดพันธุ์, สำนักพิมพ์โอเดียนสโตร์ กรุงเทพฯ. 316 หน้า.