An Updated Model for Fast Total Solids Content Determination in Natural Rubber Latex Using Shortwave Near Infrared Spectroscopy

Main Article Content

Panmanas Sirisomboon

บทคัดย่อ

The analysis of total solids content (TSC) of Para rubber latex including field latex and concentrated latex, using near-infrared spectroscopy was carried out by a ultra violet/visible/near-infrared (UV/VIS/NIR) Spectrometer in transmittance mode over the wavelength range of 350–1100 nm. The original model provided the best accuracy of prediction was developed using the partial least square regression (PLSR) from the spectra which were pretreated by the smoothing and range normalization in the wavelength range of 700-950 nm. The slope, offset, correlation coefficient (r), standard error of prediction (SEP) and bias were 1.0084, -0.2332, 0.9940, 1.3611% and 0.1456%, respectively. The updated model was done by adding the 160 samples merged into the 280 original samples. The slope, offset, correlation coefficient (r), standard error of prediction (SEP) and bias were 0.9795, 0.7150, 0.9834, 1.6186% and -0.0802%, respectively. Therefore, the robust updated model by NIRS technique was more accurate and faster method for determining the TSC of Para rubber latex, for both field latex and concentrated latex.

Article Details

บท
Post-harvest and food engineering

References

Albanell, E., Miñarro, B., Carrasco, N. 2012. Detection of low-level gluten content in flour and batter by near infrared reflectance spectroscopy (NIRS). Journal of Cereal Science 56(2), 490-495.

Blackley, D.C. 1997. Polymer Latices, Vol. 1, 2nd Edition, Chapman & Hall, London,

Haughey, S.A., Graham S.F., Cancouët, E., Elliott, C.T. 2013. The application of near-infrared reflectance spectroscopy (NIRS) to detect melamine adulteration of soya bean meal. Food Chemistry, 136(3–4), 1557-1561.

Huang, H., Yu, H., Xu, H., Ying, Y. 2008. Near infrared spectroscopy for on/in-line monitoring of quality in foods and beverages: A review. Journal of Food Engineering 87(3), 303-313.

ISO 124:2011(E) Latex, rubber – Determination of total solids content.

Miralbés, C. 2004. Quality control in the milling industry using near infrared transmittance spectroscopy. Food Chemistry 88(4), 621-628.

Sirisomboon P, Chowbankrang R, Williams P. 2012. Evaluation of apparent viscosity of Para rubber latex by diffuse reflection near-infrared spectroscopy. Applied Spectroscopy 66(5), 595-599.

Sirisomboon, P., Deeprommit, M., Suchaiboonsiri, W., Lertsri, W. 2013b. Shortwave near infrared spectroscopy for determination of dry rubber content and total solids content of Para rubber latex. Journal of Near Infrared Spectroscopy 2, 269–279.

Sirisomboon, P., Kaewkuptong, A., Williams, P. 2013a. Feasibility study on the evaluation of the dry rubber content of field and concentrated latex of Para rubber by diffuse reflectance near infrared spectroscopy. Journal of Near Infrared Spectroscopy 21, 81–88.

Williams, P. 2010. Near-infrared Technology – Getting the best out of light. A short course in the practical implementation of near-infrared spectroscopy for the user. 5.4. ed. PDK Grain, Nanaimo, Canada.